EGC Hydraulic Gear Pumps

- Model Code
- Feature
- Technical Data
- Dimension
- Performance Curves
- Operating Instruction
- Drive System
- Notification
- High volume, high efficiency and high pressure.
- Special gear design, noise is very low.
- Compace body and space saving.
- Aluminum alloy, gravity casting body.
- Light weight and sturdiness.
- Standard SAE two ports flange.
| Model | Theoretical Displacement | Operating Pressure | Shaft Speed Range (rpm) | Dimension (mm) | In/Outlet Dimension (mm) |
|||||
|---|---|---|---|---|---|---|---|---|---|---|
| continuous | Max. Pressure | Peak Pressure | ||||||||
| (c.c./rev.) | (kgf/cm²) | (kgf/cm²) | (kgf/cm²) | Max. | Min. | A | B | Inlet | Outlet | |
| EGC-19 | 19 | 230 | 250 | 280 | 3600 | 600 | 66 | 132 | 25 | 18.5 |
| EGC-22 | 22 | 210 | 230 | 250 | 3600 | 600 | 68 | 136 | 25 | 18.5 |
| EGC-26 | 26 | 210 | 230 | 250 | 3600 | 600 | 70.5 | 141 | 25 | 18.5 |
| EGC-32 | 32 | 190 | 210 | 230 | 3600 | 600 | 75 | 150 | 25 | 18.5 |
- Pump must be located with driving shaft coaxial to power take off. The drive system must not impose axial or radial load to pump shaft.
- Hydraulic fluid
Use a mineral based hydraulic oil with additive to resist oxidatioon, Corrosion and foaming or an engine oil.
Recommend viscosity
Mineral oil 3÷5 E 50°C --- Enging oil SAE 10,20,30 depending on environment temperature.
Operating Temperature range: 15 - 70°C
Viscosity: 1.45 E
Maximum viscosity during starting: 200 °E - Filtration
Before filling the system, ensure that circuit is perfectly clean. Filter must be adequate in capacity and preferably with blockage indicators. Filter must be changed according to operating instruction. Recommended filtering: Suction side 90 mesh, Return side 25 medium porosity. - Piping Instruction
Avoid sharp bends and restrictions on the circuit.
Maximum inlet depression: 250mm/Hg
Maximum oil speed suction side: 0.5÷1.5 Mt/sec
Maximum oil speed outlet side: 3÷8 Mt/sec
Maximum oil speed return side: 2÷3 Mt/sec
- No radial or axial forces may be permitted to act on the pump drive shaft.
- The alignment of motor and pump must be adjusted precisely.
- Always use a coupling which will permit compensation for any shaft displacement.
- When mounting the coupling, avoid applying axial force, i.e. never attempt to press or knock into place using a hammer or similar instrument.
- Every pumps supplied by Camel have been passed by performance and function testing.
Any attempts to modify the pump is not allowed and will not keep the warranty.
Maintenance must be performed by the manufacturer or by authorized dealers. No warranty can be accepted for unauthorized repairs. - Repairs may only be performed by the manufacturer or by authorized dealers and branches. No warranty can be accepted for unauthorized repairs.






555.com.tw